Products

CO2 recovery

CO2 recovery technologies help reduce operating costs, improve production efficiency and make better use of gas across the entire process.

Efficient CO2 utilization in operation

CO2 recovery is suitable for operations that want to manage gas more efficiently, reduce losses and increase technology efficiency. We design each solution with regard to specific operating conditions and required output.

Need a suitable solution designed?

We will help you choose the technology according to your operation type, production volume and specific application.

We can advise you
RECOVER K500
High-pressure tank

RECOVER K500

Compact CO2 recovery technology for smaller operations.

RECOVER K500 is a modular high-pressure CO2 tank with a stainless-steel frame. It can be handled lengthwise or crosswise, stacked and positioned vertically, horizontally or on either side.

Technical specifications

Maximum pressure 200 bar
Dimensions 2400 × 820 × 650 mm
Volume 500 l
Empty vessel weight 480 kg
CO2 capacity 400 kg
Stackability
Handling lengthwise and crosswise
Attachment crane hook
Positioning vertically, horizontally and on both sides
Frame construction stainless steel
Construction modulární
Price 4 000 EUR

Optional equipment / options

  • High-pressure tank for CO2
  • Modular construction
  • Stainless-steel frame
  • Stackable system
  • Can be handled by crane
RECO₂VER 6-10KF
Rekuperace CO₂

RECO₂VER 6-10KF

CO2 recovery unit for beverage and production operations.

A technology for recovering CO2 from process gas and returning it for further use in the operation.

Technical specifications

Output 3,5 m³ = 6 kg CO₂/h = 120 kg/den
Fermentation vessel capacity max. 200 hl (pivo)
Achieved gas concentration CO₂ 99,9 %
Outlet pressure to CO2 storage max. 10 bar
Fermentation CO2 inlet pressure 5 to 15 kPa
Inlet vessel and washer 100 l – SS 304 / 20 l vody
Retention vessel 24 l – SS 304
Drain valve Servo NO 1/2″
Compressor unit DU KK A100, 60 l/min, 10 bar, 0,9 kW
PARKER filtration AO, AA 99,9999 %
CC100-500 carbon filter 200 l/min, 10 bar
Passive condensation unit SS 50 l with automaticic draining
Active dryer FR 24C with automaticic draining
Control panel IP 64
Power supply 240 V, 1,0 kW
Electricity consumption per 1 kg CO2 0,166 kWh
Operating noise level 68 dB
Operating environment +5 °C to +40 °C
Dimensions W x H x D 1200 × 1500 × 800 mm
Weight 155 kg
Plug & play system price 16 880 EUR
Spare parts for 2 years of operation 1 240 EUR
Delivery time 4 to 8 weeks

Optional equipment / options

  • Delivered connected on a frame as plug & play
  • Inlet gas water washer
  • Passive and active condensation section
  • Carbon and outlet filtration
  • Automatic opening of the drain valve when the unit is switched off
RECO₂VER 8S
Rekuperace CO₂

RECO₂VER 8S

CO2 recovery solution with compact process integration.

A recovery system designed to improve CO2 utilization and reduce operating costs in production technology.

Technical specifications

Output 4 m³ = 8 kg CO₂/h = 200 kg/den
Fermentation vessel capacity 15 m³ (víno) to 35 m³ (pivo)
Achieved gas concentration CO₂ 99,7 %
Achieved gas purity 0,01 PPM
Outlet pressure to CO2 storage max. 8,0 bar
Fermentation CO2 inlet pressure 5 to 25 kPa
Retention vessel capacity - CO2 inlet 50 l – SS 304
Compressor unit DK B100, 70 l/min, 8 bar
PARKER filtration AO, AA 99,9999 %
CC100-500 carbon filter 300 l/min, 10 bar
Condensation units passive 30 l + dryer PARKER Hiross 24C
Operating environment +5 °C to +40 °C
Power supply 240 V, 0,9 kW
Electricity consumption per 1 kg CO2 0,11 kWh
Operating noise level 60 dB
Dimensions W x H x D 1200 × 700 × 500 mm
Weight 90 kg
Unit price 7 680 EUR
Condensation and filtration unit price 2 450 EUR
Delivery time 6 to 8 weeks

Optional equipment / options

  • Option to add a 100 l gas washer
  • Optional MPEX 500 l / 10 bar storage vessel
  • Optional JADR manual recovery adapter
  • Optional KEG depressurization unit
  • Can be installed on a platform or in an enclosed cabinet
RECO₂VER 12-10KF
Rekuperace CO₂

RECO₂VER 12-10KF

CO2 recovery technology for larger production volumes.

A system for operations that need efficient CO2 recovery, stable performance and reliable integration into the production process.

Technical specifications

Output 7 m³ = 12 kg CO₂/h = 240 kg/den
Fermentation vessel capacity max. 400 hl (pivo)
Achieved gas concentration CO₂ 99,9 %
Outlet pressure to CO2 storage max. 10 bar
Fermentation CO2 inlet pressure 5 to 15 kPa
Inlet vessel and washer 100 l – SS 304 / 20 l vody
Retention vessel 24 l – SS 304
Drain valve Servo NO 1/2″
Compressor unit DU KK A200, 120 l/min, 10 bar, 1,4 kW
PARKER filtration AO, AA 99,9999 %
CC100-500 carbon filter 200 l/min, 10 bar
Passive condensation unit SS 50 l with automaticic draining
Active dryer FR 24C with automaticic draining
Control panel IP 64
Power supply 240 V, 1,8 kW
Electricity consumption per 1 kg CO2 0,15 kWh
Operating noise level 70 dB
Operating environment +5 °C to +40 °C
Dimensions W x H x D 1200 × 1500 × 800 mm
Weight 170 kg
Plug & play system price 19 650 EUR
Spare parts for 2 years of operation 1 840 EUR
Delivery time 4 to 8 weeks

Optional equipment / options

  • Delivered connected on a frame as plug & play
  • Suitable for breweries with higher fermentation capacity
  • Inlet gas water washer
  • Passive and active condensation section
  • Automatic removal of foam and condensate residues
RECO₂VER 12-300-10
Rekuperace CO₂

RECO₂VER 12-300-10

CO2 recovery system with storage capacity for process use.

A recovery solution designed for operations where recovered CO2 is stored and reused as part of production technology.

Technical specifications

System output 6 m³ = 12 kg CO₂/h
Total connected CCT capacity max. 400 hl = to 250 kg CO₂/den
Achieved gas concentration CO₂ 99,95 %
Achieved gas purity 0,01 PPM
Outlet pressure to CO2 storage max. 10 bar
Captured CO2 inlet pressure 0,05 to 0,20 bar
Capture tank capacity 300 l – stainless steel
Compressor DURR KK70 A200, 100 l/min, 10 bar
CO2 treatment process pressure 6 to 10 bar
Integrated filtration column AA, AC, AX 99,9999 %
CC100-500 coalescing unit 500 l/min, 10 bar
Drain points 5× (3× automatic)
Operating environment +5 °C to 30 °C
Power supply 1×240 V, 1,6 kW
Electricity consumption per 1 kg CO2 130 W
Compression operating noise level 69 dB
System dimensions W x D x H 800 × 950 × 1730 mm
Weight 174 kg
Unit price 435 500 CZK
K50 passive condenser 32 600 CZK
AK30 CO2 condensation dryer 43 800 CZK
Installation and commissioning 15 000 CZK
Delivery time 10 to 15 weeks

Optional equipment / options

  • For breweries producing up to 15,000 hl per year
  • Integrated filtration column
  • Optional electronic CO2 flow measurement
  • Optional measuring unit for CO2/O2 gas monitoring
  • Service after 1,000 operating hours or 12 months
RECO₂VER 25-600-10-Dual
Rekuperace CO₂

RECO₂VER 25-600-10-Dual

Dual CO2 recovery system for demanding applications.

A high-capacity recovery solution for operations with higher CO2 volumes and emphasis on efficient gas reuse.

Technical specifications

System output 13 m³ = 25 kg CO₂/h
Total connected CCT capacity max. 1500 hl = to 500 kg CO₂/den
Achieved gas concentration CO₂ 99,9 %
Achieved gas purity 0,01 PPM
Outlet pressure to CO2 storage max. 10 bar
Captured CO2 inlet pressure 0,05 to 0,25 bar
Capture tank capacity 2×300 l – stainless steel
Compressor DURR KK70 B200 2×, 200 l/min, 8 bar
CO2 treatment process pressure 6 to 10 bar
Integrated filtration column AA, AC, AX 99,9999 %
CC100-500 coalescing unit 1000 l/min, 10 bar
Drain points 5× (3× automatic)
Operating environment +5 °C to 30 °C
Power supply 3×400 V, 3,2 kW
Electricity consumption per 1 kg CO2 130 W
Compression operating noise level 73 dB
System dimensions W x D x H 1600 × 950 × 1730 mm
Weight 354 kg
Unit price 675 800 CZK
K100 passive condenser 44 800 CZK
AK50 CO2 condensation dryer 54 800 CZK
Installation and commissioning 20 000 CZK
Delivery time 10 to 15 weeks

Optional equipment / options

  • For breweries producing up to 50,000 hl per year
  • Pair of 300 l capture tanks
  • Dual-compressor design
  • Optional electronic CO2 flow measurement
  • Service after 1,000 operating hours or 12 months

Typical applications

CO2 recovery is useful wherever gas savings and operating efficiency are important.

Microbreweries
Beverage production
Food production facilities
Technology lines using CO2
Cost-saving production
Operations requiring higher efficiency

Do you want to improve CO2 utilization in your operation?

Contact us. We will propose a suitable CO2 recovery solution according to technical requirements and the nature of your operation.

Request a quote